(2009) Field Instrumentation, Testing, and Long-Term Monitoring of High-Mast Lighting Tower No. 1 at the I-35/US 18 Interchange Near Clear Lake in the State of Iowa Phase 3, TR-562, 2009. Transportation, Department of
|
PDF
IADOT_tr_562phase3_Field_Instrument_Testing_Lighting_Tower_I_35_Near_Clear_Lake_2009.pdf File Size:2MB |
Abstract
The current study was initiated to quantify the stresses induced in critical details on the reinforcing jacket and the tower itself through the use of field instrumentation, load testing, and long-term monitoring. Strain gages were installed on the both the tower and the reinforcing jacket. Additional strain gages were installed on two anchor rods. Tests were conducted with and without the reinforcing jacket installed. Data were collected from all strain gages during static load testing and were used to study the stress distribution of the tower caused by known loads, both with and without the reinforcing jacket. The tower was tested dynamically by first applying a static load, and then quickly releasing the load causing the tower to vibrate freely. Furthermore, the tower was monitored over a period of over 1 year to obtain stress range histograms at the critical details to be used for a fatigue evaluation. Also during the long-term monitoring, triggered time-history data were recorded to study the wind loading phenomena that excite the tower.
Item Type: | Departmental Report |
---|---|
Keywords: | Collapse, Deformation curve, Fatigue (Mechanics), Field tests, High mast lighting, Installation, Instrumentation, Load tests, Monitoring, Retrofitting, Static and dynamic tests, Stresses, Structural analysis, Towers |
Subjects: | Transportation Transportation > Bridges and tunnels Transportation > Roads and highways Transportation > Design and Construction Transportation > Maintenance and preservation |
ID Code: | 20061 |
Deposited By: | Iowa DOT Library |
Deposited On: | 07 Jul 2015 12:23 |
Last Modified: | 07 Jul 2015 12:23 |
URI: | https://publications.iowa.gov/id/eprint/20061 |