Research Solutions: Evaluation of Galvanized and Painted Galvanized Steel Piling, April 2024

(2024) Research Solutions: Evaluation of Galvanized and Painted Galvanized Steel Piling, April 2024. Transportation, Department of

[img]
Preview
PDF
TR-766-Evaluation_of_Galvanized_and_Painted_Galvanized_Steel_Piling.pdf

File Size:363kB

Abstract

Steel pile foundation systems need to perform over a bridge’s service life, making corrosion an important consideration in the design and upkeep of these systems. Iowa DOT pursued options to combat steel’s natural process of corrosion when exposed to moisture, oxygen, and soil properties. New research indicates that galvanized and painted galvanized steel pilings are highly corrosion-resistant. But another solution — increasing the the pile section size — allows for section loss from corrosion while still providing the required design strength. Considering the costs of steel and galvanizing practices, larger piles are the economical solution.

Item Type: Departmental Report
Keywords: accelerated corrosion, testing—economic cost, analysis—in situ field, testing—galvanize, piles—painted galvanized, piles
Subjects: Transportation
Transportation > Bridges and tunnels
Transportation > Research
ID Code: 48445
Deposited By: Iowa DOT Research
Deposited On: 03 Apr 2024 20:36
Last Modified: 03 Apr 2024 20:36
URI: https://publications.iowa.gov/id/eprint/48445