Interlaboratory Study to Determine the Precision of the MIT Scan T2 for PCC Pavement Thickness, MLR 14-01, 2015

(2015) Interlaboratory Study to Determine the Precision of the MIT Scan T2 for PCC Pavement Thickness, MLR 14-01, 2015. Transportation, Department of

[img]
Preview
PDF
IADOT_MLR_14_01_Interlaboratory_Study_Determine_Precision_MIT_Scan_2015.pdf

File Size:1MB

Abstract

The MIT Scan T2 device has been implemented in Iowa as a new method for determining PCC pavement thickness compliance. The T2 device utilizes a magnetic pulse induction technology to measure the distance from a sensor to a metal target. The objective of this project was to conduct an interlaboratory study (ASTM C802) to determine the precision of the test.Fifteen MIT Scan T2 gauges and fifteen operators performed testing on three reference platforms and nine pavement locations of varying thicknesses. The testing was conducted on October 29, 2014 at two sites near Ames, Iowa. Usable data was obtained from every operator at all locations.

Item Type: Departmental Report
Keywords: Nondestructive tests, Portland cement concrete, Thickness, Pavements
Subjects: Transportation > Pavements
Transportation > Pavements > Concrete
Transportation
Transportation > Roads and highways
ID Code: 21924
Deposited By: Iowa DOT Library
Deposited On: 21 Apr 2016 18:55
Last Modified: 21 Apr 2016 18:55