Implementation of a Pilot Continuous Monitoring System: Iowa Falls Arch Bridge, HR-1088, 2015

(2015) Implementation of a Pilot Continuous Monitoring System: Iowa Falls Arch Bridge, HR-1088, 2015. Transportation, Department of

[img]
Preview
PDF
IADOT_ISU_HR_1088_Phares_Imp_Pilot_Continuous_Monitoring_System_ Iowa_Falls_Arch_Bridge_2015_Final.pdf

File Size:6MB
[img]
Preview
PDF
IADOT_ISU_HR_1088_Phares_Imp_Pilot_Continuous_Monitoring_System_ Iowa_Falls_Arch_Bridge_2015_Summary.pdf

File Size:410kB

Abstract

The goal of this work was to move structural health monitoring (SHM) one step closer to being ready for mainstream use by the Iowa Department of Transportation (DOT) Office of Bridges and Structures. To meet this goal, the objective of this project was to implement a pilot multi-sensor continuous monitoring system on the Iowa Falls Arch Bridge such that autonomous data analysis, storage, and retrieval can be demonstrated. The challenge with this work was to develop the open channels for communication, coordination, and cooperation of various Iowa DOT offices that could make use of the data. In a way, the end product was to be something akin to a control system that would allow for real-time evaluation of the operational condition of a monitored bridge. Development and finalization of general hardware and software components for a bridge SHM system were investigated and completed. This development and finalization was framed around the demonstration installation on the Iowa Falls Arch Bridge. The hardware system focused on using off-the-shelf sensors that could be read in either “fast” or “slow” modes depending on the desired monitoring metric. As hoped, the installed system operated with very few problems. In terms of communications—in part due to the anticipated installation on the I-74 bridge over the Mississippi River—a hardline digital subscriber line (DSL) internet connection and grid power were used. During operation, this system would transmit data to a central server location where the data would be processed and then archived for future retrieval and use. The pilot monitoring system was developed for general performance evaluation purposes (construction, structural, environmental, etc.) such that it could be easily adapted to the Iowa DOT’s bridges and other monitoring needs. The system was developed allowing easy access to near real-time data in a format usable to Iowa DOT engineers.

Item Type: Departmental Report
Keywords: Arch bridges, Bridges, Durability, Implementation, Infrastructure, Mobility, Monitoring, Safety, Sensors, Structural health monitoring, Iowa Falls, HR-1088
Subjects: Transportation
Transportation > Bridges and tunnels
Transportation > Data and Information Technology
Transportation > Maintenance and preservation
ID Code: 20131
Deposited By: Leighton Christiansen
Deposited On: 10 Jul 2015 20:03
Last Modified: 10 Jul 2015 20:03
URI: https://publications.iowa.gov/id/eprint/20131