Investigation of Unbraced Pile Height in Fully-Encased Pile Bents of Bridge Structures - SPR-RE23(008)-8H-00

(2023) Investigation of Unbraced Pile Height in Fully-Encased Pile Bents of Bridge Structures - SPR-RE23(008)-8H-00. Transportation, Department of

[img]
Preview
PDF
Iowa DOT Research in Progress - RE-23008 - Final.pdf

File Size:615kB

Abstract

A project recently completed for the Iowa Department of Transportation investigated the contributions of concrete encasements of steel H-piles used for bridges which have historically not been considered in the design process. The initial reason for the project was to determine the remaining capacity of a pile when subjected to scour, leaving bare the uncased portion of a pile. A tool was developed to calculate capacity and a subsequent laboratory investigation was completed to validate the pile capacity assessment tool. The study concluded the pile capacity is greater than what has been otherwise calculated. As a secondary result, consideration has been given to revising the capacity calculations of new piles especially in fully-encased pile bents. This project aims to identify the unbraced height limits of steel H-piles when fully-encased.

Item Type: Departmental Report
Keywords: Bridge Piles Concrete Encasements Fully-encased Pile Bents Steel H-piles
Subjects: Transportation
Transportation > Materials
Transportation > Bridges and tunnels
Transportation > Research
ID Code: 44091
Deposited By: Iowa DOT Research
Deposited On: 19 Apr 2023 13:30
Last Modified: 19 Apr 2023 13:30
URI: https://publications.iowa.gov/id/eprint/44091