Using the Air Void Anal Analyzer for Real-Time Quality Control Adjustments in the Field, November 2004

(2004) Using the Air Void Anal Analyzer for Real-Time Quality Control Adjustments in the Field, November 2004. Iowa State University

[img]
Preview
PDF
AVAtech.pdf

File Size:550kB

Abstract

The air void analyzer (AVA) with its independent isolation base can be used to accurately evaluate the air void system—including volume of entrained air, size of air voids, and distribution of air voids—of fresh portland cement concrete (PCC) on the jobsite. With this information, quality control adjustments in concrete batching can be made in real time to improve the air void system and thus increase freeze-thaw durability. This technology offers many advantages over current practices for evaluating air in concrete.

Item Type: Departmental Report
Keywords: air void analyzer, cement, concrete, PCC
Subjects: Transportation > Research
Transportation > Research > Concrete
Transportation > Roads and highways
Transportation
ID Code: 2943
Deposited By: Margaret Barr
Deposited On: 27 Oct 2005
Last Modified: 27 Oct 2005