(2004) Using the Air Void Anal Analyzer for Real-Time Quality Control Adjustments in the Field, November 2004. Iowa State University
|
PDF
AVAtech.pdf File Size:550kB |
Abstract
The air void analyzer (AVA) with its independent isolation base can be used to accurately evaluate the air void system—including volume of entrained air, size of air voids, and distribution of air voids—of fresh portland cement concrete (PCC) on the jobsite. With this information, quality control adjustments in concrete batching can be made in real time to improve the air void system and thus increase freeze-thaw durability. This technology offers many advantages over current practices for evaluating air in concrete.
Item Type: | Departmental Report |
---|---|
Keywords: | air void analyzer, cement, concrete, PCC |
Subjects: | Transportation > Research Transportation > Research > Concrete Transportation > Roads and highways Transportation |
ID Code: | 2943 |
Deposited By: | Margaret Barr |
Deposited On: | 27 Oct 2005 |
Last Modified: | 27 Oct 2005 |
URI: | https://publications.iowa.gov/id/eprint/2943 |