Laboratory Testing of SHRP SPS-2 P.C.C. Mixes, MLR-94-5, 1995

(1995) Laboratory Testing of SHRP SPS-2 P.C.C. Mixes, MLR-94-5, 1995. Transportation, Department of

[img]
Preview
PDF
IADOT_mlr9405_Lab_Test_SHRP_SPS-2_PCC_Mix_1995.pdf

File Size:205kB

Abstract

This research evaluated the concrete strength of two mixes which were used in the Polk County project NHS-500-1(3)--10-77 and were developed to meet a contract requirement of 900 psi third-point 28-day flexural strength. Two concrete mixes, the Proposed Mix and the Enhanced Mix, were tested for strength. Based on the experimental results, it was found that the addition of 50 lb of cementitious materials did not significantly increase concrete strength. The requirement of 900 psi 28-day third-point flexural strength (MOR-TPL) was not achieved by this amount of addition of cementitious materials.

Item Type: Departmental Report
Keywords: Cement content, Concrete, Flexural strength, Laboratory tests, Mix design, Portland cement concrete, Strength of materials
Subjects: Transportation
Transportation > Roads and highways
Transportation > Research
Transportation > Research > Concrete
ID Code: 16756
Deposited By: Iowa DOT Library
Deposited On: 02 May 2014 11:38
Last Modified: 07 Jan 2015 21:16